BRAND | Badger Meter |
Product | P/N: 167541 Type: 1005 2F66 56547 163 2F66 |
Description | turbine measuring station |
Internal code | IMP4465165 |
Custom code | 90261081 |
Technical specification | Vision 1000 - 2F66 Trogamid with DIN device socket with power socket Housing: Trogamid Rotor: PA12 ferrite Bearing: PTFE/graphite Measuring range: 0.1 - 2.5 l/min Accuracy: +/- 3% of the value Pulse tap: Hall generator p-max: 25 bar t-max: 100 °C Connections: G 1/4" El. Connection: pin plate with 3 spade connectors (2.8 x 0.5) and DIN plug, EN 60529 bore: 5 mm Installation length: approx. 45 mm Installation position: arbitrary K-factor: Approx. 22000 pulses/liter Power supply: 5-24 VDC |
Discover the superior quality and performance of the Badger Meter P/N: 167541 Type: 1005 2F66 56547 163 2F66 with Impexron GMBH in Germany . Whether you are looking for reliability or efficiency, this product meets all your industrial needs.
The P/N: 167541 Type: 1005 2F66 56547 163 2F66 is designed to provide optimal performance and durability in various applications. Known for its high-quality construction and innovative features, it is a preferred choice for professionals.
Key Features of P/N: 167541 Type: 1005 2F66 56547 163 2F66 :
At Impexron GMBH , we offer the P/N: 167541 Type: 1005 2F66 56547 163 2F66 at competitive prices and with the fastest delivery times across Germany . Our expert team is ready to assist you with all your inquiries and provide tailored solutions to meet your specific needs.
Why Choose Impexron GMBH ?
Get Your Quote Today! Ready to enhance your operations with the P/N: 167541 Type: 1005 2F66 56547 163 2F66 ? Contact us now for a personalized quote. Fill out the form below or send us an email with your inquiry. Let us help you make a cost-effective, quality-driven choice for your business.
Important Notice: While we supply Badger Meter products, Impexron GMBH is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.
Register with pulse output, Electronic counter LCR type with an LCD display and, pulse output above for OG-Baureihe.Anzeige 1: resettable totalizer or flow indication programmable, Format xxxx.x. Display 2: Non-resettable totalizer, 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64 For counter Size: M25-M35-M40-M70-M120-M170 Pulse output: NPN, MOSFET 40V / 2A Pulse factor: 0.01-99.99 Pulse length: 10ms (2ms, 20ms, 40ms) Ext.Stromversorg. : 8-24VDC Pulse output PPL: 0,01-0,1-1-10-100 Dosing control: 0.01 to 999.99 Preliminary circuit: from 0.00 to 99.99 Switching output: NPN, MOSFET 40V / 2A
RCDL LCR REGISTER MIT IMPULSAUSGANG U. STROMAUSGANG 4-20MA
Electronic counter LCR type with an LCD display, Display 1: resettable totalizer or Flow display programmable, Format xxx.xx. Display 2: Non-resettable totalizer 14 digits. Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA
RCDL LCR REGISTER OHNE IMPULSAUSGANG
Electronic counter LCR type with an LCD display, for the OG series Display 1: resettable totalizer or Flow display programmable, format xxxx.x Display 2: Non-resettable totalizer 14 digits Memory display: EEPROM, data retention in battery replacement Units: liters, gallons, pints, quarts Temperature: 0-70 ° C Pulse acquisition: Reed, max.50Hz Input pulse: from 1.00 to 17000.00 (numerator) Correction factor: 0.5000 to 2.0000 Power supply: 3 VDC Lithium CR 1/2 AA Protection: IP 64
3/4 "or 1" PPO Viton without pulse, fluid meter RCDL M25 without construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, standing
Vectra Viton pulse PFT-2 reed contact Liquid meter RCDL M25 without construction. Materials and technical data: Housing: Bronze Measuring chamber: Vectra O-rings: Viton Measuring range: 3-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: ° C Connection: R 1 "outside Installation length: 190 mm Installation position: horizontal, standing 604011 Pulse PFT-2 reed contact about 52 PPL
liquid meter
RCDL M25 3/4" ODER 1" PPO VITON OHNE IMPULSGEBER
(Liquid meter RCDL M25 without Construction. Material and technical data: Housing: Nylon Measuring chamber: Noryl (PPO) O-rings: Viton Measuring range: 1-100 l / min Accuracy: +/- 1.5% of the value p-max: 10 bar t-max: 50 ° C Connection: R 3/4 "or R 1" Installation length: 190 mm Installation position: horizontal, vertical)
RCDL M25, WITH PULSE- TRANSMITTER PFT-1E - 52,4 PULSE/LITER SETUP
Housing : Bronze Chamber : Noryl (PPO) O-Rings : Buna Flowrange : 1-100 l/min Accuracy : +/- 1,5 % of value p-max : 10 bar t-max : 50 °C Connection : Threads 1" male Laylength : 190mm Pulsoutput : Open Collector NPN Scale Factor : 0.00001 to 0.9999 Supply : 12-24 VDC Pulsoutput : S/N : Part-Nr. 141158
MID M 2000 mit Flansch DN 50 1.4571
Oval wheel counter
PN : MID M 1000, Type : Typ ModMAG M1000
magnetic inductive flowmeter
Electromagnetic Flow Meter
Pulse Flow meter
P/N: 9008527 Type: MID M 1000 DN 50/16
Magnetisch-Induktiver-Durchflußmesser
Magnetisch-Induktiver-Durchflußmesser
102460 LM OG-PNDA electronic preset counter
Elektronischer Vorwahlzähler
MN 2 ASP – 1 obsolete/replaced by IOG BSP 1/4" ALU 1.4571
flowmeter for diesel
Impulsgeber
Signal Transmitters
MID2-25/16- F/St-HG- MEL/HC-St
flowmeter
magnetic flow meter