FLHK-012440-012441  - Schniewindt Germany  Sales

BRAND Schniewindt
Product FLHK-012440-012441
Internal code IMP4443717
Technical specification CSN® flange radiators 96/F-27-440 Technical data: Supply voltage [V] 440.00 Number of switching stages 1 Output level 1 [kW] 27,000 Total power [kW] 27,000 Standard power tolerance (+5/-10%) Tol. related to hot output Upper warm tolerance (%) 5 Lower warm tolerance (%) -10 Star interconnection Neutral wire yes Protection class IP 54 Horizontal installation position Installation length [mm] 1360,0 Installation length upper tol. [mm] 0 Installation length lower tol. [mm] -35 Unheated length [mm] 170 Heating element type RHK number of RHK 9 Number of RHKs with reserve 9 Diameter [mm] Ø 11.5 mm Curved design Surface load [W/cm²] 3.49 Pipe material 1.4571 Stud material nickel-plated steel Type of fastening welded Closure type Giso-G Steel spacer Spacer pipe length [mm] 104 FLANGE NORM ASME B16.5 nominal diameter 6" Class 150 pressure rating Materials 1.4571 Deflection segment type Diameter [mm] 148.0 count 6 Fixation With, fixed to flange terminal box design/material CSN standard, steel, RAL 7035 Dimensions (W x H x D in mm) 300 x 300 x 160 Number of thermostats/sensors in heating bundle 1 Temperature detection type limiter Temperature detection limiter, 20/500°C, EM-5, 1000/6x280 mm Temperature detection interconnection external control Temperature detection indoor setting thermal bridge type pipe fittings brazed Thermal bridge length [mm] 120 interconnection stage 1 connection terminal potting interconnection Giso-G Control cabinet heating with Climate connector with Standard design, black Painting terminal box Standard execution Color (RAL) 7035 Old Part Number 7062331363274040988 Operating conditions: medium air Volumetric flow 2547.0 Volume flow unit Nm³/h Inlet temperature [°C] 45 outlet temperature [°C] 70 (TS) - design temperature min. [°C] -5 (TS) - design temperature max. [°C] 100 Ambient temperature min. [°C] 5 Max. ambient temperature [°C] 55 (PS) - maximum design pressure [bar] (g) 16.0 Pressure test required Yes (PT) test pressure [bar] (g) 23.0 Operating pressure [bar] (g) 12.0 classification according to the PED Article 4.3 AD 2000 standard

Please Contact Us to Order to offer competitive prices and delivery time for Schniewindt - FLHK-012440-012441 number, also you may ask some other model number is well. We can offer competitive price, and delivery time with wide products distribution network in Germany Industrial products Market. 

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

Our company is not an authorized distributor. All rights are reserved by the manufacturers and their official partners.

More products of Schniewindt

214093120313142 (801F/KRC-EXDE24T3)

(CSN Ex-flange heaters 801F / KRC-Exde24T3 Power (kW): 24 + 5 / -10% Voltage: 380 V 3 ~ rating)

90N/G2-60.000.001.364.411

(CSN® Patronenheizkörper)

93/F53-50RB-CSA

Drawing Number sketch Circuit AC perm. Ansc ambient temperature at -20 to + 40 ° C Protection IP 65 Installation Horizontal Mounting length (mm) 500 unheated length (mm) 50 Medium phosphate ester Operating 70 perm. min / max temp. (° C) -20 ° C ..80 to. Max. PS Pressure (bar g) 0.5 Heater ceramic heater DIN 2527 / EN 1092-1 DN 80 Pressure stage PN16 1.4571 Diameter casing tube (mm) 52 Surface load (W / cm²) 1.36

93S/FS-EEX1.0T

CSN Ex-cartridge heaters, rated power (kW): 1.0 / Rated voltage: 230V

EIGTB / 180 35 15

Rated power: 15 kW Rated voltage: 400 V 3 ~ Circuit: Triangle / 1-stage IP 54 Installation length: 1800 mm, of which 1450 mm unheated Minimum immersion depth: 450 mm Mounting position: vertically from above Fitting: G 2 "SW 70 - ISO 228 - Brass Tubular heating element (RHK): 3 Pieces 8.5 mm from 1.4571 - soldered, 400 volt, 5000 watt, 5.0 W / cm² Outer diameter (RHK): 145 mm Flange: Ø 285 x 22 to 8 x Ø 22 LK 240 from 1.4571 Connection housing: aluminum, lacquered - Red RAL 3000 - 120 x 120 x 150 mm Controls: 1-pole 0-85 ° C (~ 250V / 10A), - internal setting Limiter: 1 pole 0-150 ° C (~ 250V / 10A), - internal setting Media: cooling water Operating temperature: 5 ° C (anti-freeze heater) Perm. Temperature following range: max. 80 ° C Perm. Operating pressure: max. 10 bar g

EIGTB/125 45 15 - OLD NUMBER, NEW NUMBER EIGTB /180 35 15

CSN Tankheizkorper A10-749786.1.1 400 V 3 15kW 1800mm IP 54

ERCB / 50

(CSN Screw Type: ERCB / 50 Power: 3000 W Voltage: 460 V 3N ~ Circuit: Star IP 54 Installation length: 500 mm, 70 mm unheated Mounting position: horizontal or vertical Gland: G 1 1/2 "SW 65 Limiter: 1 pole 0-150 ° C - Inneneinstellung- Same as in 2010 already manufactured with Contract No .: A10-747993. Media: water (normal quality) Operating temperature: 30 ° C Operating pressure: 6 bar g)

ERCH 63,5 - 9 - 400

CSN screw-in radiator

ERCHH-61.5

Resistance,Behalt No.: 226742.2.3 Voltage: 480V 3N Power: 8000W Protection: IP 54 Year: 11/2007

ERCT/30-0,4-230

Screw-in radiator CSN

ERCTH-61.5 226742.1.2

Resistance,Voltage: 480V 3N Power: 8000W Protection: IP 54 Year: 11/2007

TYP : 96/FF (OEM for IPG)

Flange Heater Element ,2002 400V / 3 PH IP 65

TYP 90/G2-175

CSN ® Patronenheizkoerper Power (kW): 1.8 Voltage: 380V 3 ~ Y Power tolerance: +5% / -10%

TYP 90N/G2-70

CSN ® cartridge heaters

H-8.15

Feed air heate/ CSN flange heater

1ZS1030100DC045G302

HV-Damping Resistor

Type G-OI Nr 111839

HV-Filter Damping Resistor

5841616595230

CSN high-performance cartridge

1116922

HV-Damping Resistor

20105109017540

CSN Patronennheizkoerper

Other Category Brands

Contact us for request