6147/2-2   - R.Stahl Germany  Sales

BRAND R.Stahl
Product 6147/2-2
Description Hand lamp Wire guard galv
Internal code IMP1464734
Weight 2.05

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Stahl - 6147/2-2 Hand lamp Wire guard galv number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Germany Industrial products Market.

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

More products of Stahl

150551 / 8570/12-406

Plug explosion-proof

8570/12-406

(Plug explosion Proof Type: 8570 / 12-406 Bemessungsbetr.spg. / Frequency: 380-415 V 50/60 Hz Operating current: 16 A Detailed Contacts 4 P (3 P + PE) Color code: red Coding (time position): 6 Housing material: Polyamide Field of Application (zones): 1, 2, 21, 22 Gas explosion protection: II 2 G Ex de IIC T6 Dust explosion protection: II 2 D IP66 80 ° C Ambient temperature min. : -30 ° C Ambient temperature max. +55 ° C Protection (IP): IP66 Terminals: 1.5 mm Cable entry: 8 ... 20 mm plug explosion proof)

8575/12-100

PLUG,UTILITY, 2-POLES

p/n: 270900, Type: 8579/31-506

Switch socket for low temperature, explosion-proof

8602/3

Pushbutton

8602 STOP

(Button label Label marking : STOP Colour of label : red For further information, see : www.r-stahl.com Web code 8082A)

8602A0727 1-2-R-V

(Rotary handle, small lockable explosion-protected Enclosure material : Polyamide Seal : Standard Mounting : with threaded Switching function : latching Number of switching positions : 2 Construction type : vertical Application range (Zone) : 1 , 2 , 21 , 22 Gas explosion protection : II 2 G Ex e II Dust explosion protection : II 2 D Ex tD A21 Min. ambient temperature : -50 °C Max. ambient temperature : +70 °C Type of protection (IP) : IP66 For further information, see : www.r-stahl.com Web code 8082A)

9001/01-168-020-101 (158555)

Single-channel safety barriers explosion-protected

9118/11-11-10 - OBSOLETE (REPLACED BY 9118/11-11-10)

ics modul-mA isolating repeater(max vol.:8.7 V max. cur.:0.4 mA max. pow.:11mW power supp.:24 vDC)

9160/13-11-11S

BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs POWER SUPPLY SENSOR, EEX IA IIC

9160/13-11-11S

(ISpac Isolating Repeater Transmitter Supply Unit Field Circuit Ex i explosion-protected Max. Voltage Uo : 27 V Max. Current Io : 88 mA Max. Demand Po : 576 mW Nominal voltage : 24 V DC Nominal current : 70 mA Power input_W : 1,7 W Number of channels : 1 Input : 0/4 ... 20 mA with HART Output : 0/4 ... 20 mA LFD relay : Yes Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nA nC [ia] IIC T4 Dust explosion protection : II (1) D [Ex iaD])

9164/13-22-08

mA-Trennübertrager

207909 / 9165/16-11-10s

iSPAC separation transformer

201270/9165/16-11-11s

Isolator analog output

9170/10-11-11S

BARRIER: PROTECTIVE, for receiving and transmitting UNIFIED SIGNALs

9170/10-11-11S

(ISpac Isolating Repeater Switching Repeater Field Circuit Ex i explosion-protected Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Nominal voltage : 24 V DC Nominal current : 33 mA Number of channels : 1 Output / channel : 2 change over contacts LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nAc nCc [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC)

9170/10-12-21s

(ISpac Switching amplifier Field Circuit Ex i explosion-protected Type : 9170/10-12-21s Max. Voltage Uo : 10,6 V Max. Current Io : 24 mA Max. Demand Po : 64 mW Min. nominal voltage : 120 V Max. nominal voltage : 230 V Nominal current : 12 mA Number of channels : 1 Output / channel : 1 change over contact LFD relay : Yes Line fault transparency : No Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Gas explosion protection : II (1) G [Ex ia] IIC Dust explosion protection : II (1) D [Ex ia] IIIC)

9170/20-12-11S

160293, IS PACIsolating RepeaterSwitching RepeaterField Circuit Ex iexplosion-protectedType : 9170/20-12-11sMax. Voltage Uo : 10,6 VMax. Current Io : 48 mAMax. Demand Po : 128 mWNominal voltage : 24 V DCNominal current : 33 mA Number of channels : 2Output / channel : 1 change over contactLFD relay : YesLine fault transparency : NoMin. ambient temperature : -20 °CMax. ambient temperature : +70 °CDust explosion protection : II (1) D [Ex ia] IIICFor further information, see : www.r-stahl.com Web code 9170ASwitching Repeater Series 9170, Field Circuit Ex i, dual channelBasic function: binary / digital inputIntrinsically safe input: [Ex ia] IICPower supply: 24 V DCInput: acc. to EN 60947-5-6 (NAMUR)Output / channel: 1 change-over contactConnection type: Screw terminals

9176/20-12-00S

(Binary output loop-powered IS pac)

9182/10-51-11S

(ISpac Isolating Repeater Temperature Transmitter Field Circuit Ex i explosion-protected Max. Voltage Uo : 6,5 V Max. Current Io : 19,7 mA Max. Demand Po : 32 mW Nominal voltage : 24 V DC Nominal current : 70 mA Number of channels : 1 Output : 0/4 ... 20 mA active / source Limit value contact (per ch.) : without Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C Application range (Zone) : 2 Gas explosion protection : II 3 (1) G Ex nAc nCc [ia] IIC T4 Dust explosion protection : II (1) D [Ex ia] IIIC)

9185/11-35-10

FIELDBUS ISOLATING REPEATER

9194/50-01

(ISpac pac-Bus single element explosion-protected Nominal voltage : 24 V DC Min. ambient temperature : -20 °C Max. ambient temperature : +70 °C)

Contact us for request