BRAND | Labom |
Product | BR4201-A57.59-N4200-W4105-W5417 |
Internal code | IMP4587424 |
Weight | 1.5 |
Custom code | 90262040 |
Technical specification | DL2100-A4007-L23-T99-U3 BR4 BOURDON TUBE PRESSURE GAUGE with diaphragm seal connection and switch contact acc. to data sheet D3-027 2 case: NS 100 0 case design: IP 65, process connection bottom 1 design: with ex-protection A accuracy class: see data sheet 57 nominal range: 0...6 bar 59 double scale: 0...6 bari inside black, 0...0.6 MPa outside black, same font size N4 inductive contact with standard initiator (N) 200 switch function: 1 x max. open contact Ex design for inductive contact device: P+F SJ2-N / SJ3.5-N PTB 99 ATEX 2219X II 2G Ex ia IIC T4/T5/T6 Gb Ex design (ATEX) for mechanical instruments: II 2G Ex h IIC T1...T6 Gb X, II 2D Ex h IIIC Txx°C Db X Please pay attention to the application conditions, which can be taken from the data sheet and the ex-safety instructions XA_005 and XA_013. Temperature limits might be changed with implementation of EN ISO 80079-36:2016 and EN ISO 80079-37:2016 valid from 01.11.2019. electrical connection: connection plug with cable gland M20 x 1.5 and removable test cover, mat. Macrolon W4105 ADDITIONAL DESIGN: wetted parts free of silicon W5417 CUSTOMERS SPECIFICATION: Contact Settings Functionality while pointer moves clockwise Increasing pressure breaks contact Contact set to 2.0 bar Contact alignment - polarity 3- and 4+ (max) Stop pin on right hand side of contact pointer at 3 bar DL DIAPHRAGM SEAL for food / pharmaceutical / biotechnology 2 design with coupling nut see data sheet D5-025 100 process connection: DIN 11851, DN 25 / PN 40 A400 connection of meas. instrument directly welded 7 material wetted parts: stainless steel mat.-no. 1.4435 (316L) L23 system filling: Synthetic oil, free of silicon FD1 acc. to FDA 21 CFR 178.3570 / H1-registered T99 temperature, media: see below -20...+150°C U3 temperature, ambient: 0..+50 °C Spare part for fab.-no. 2001527/30/006 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Labom - BR4201-A57.59-N4200-W4105-W5417 number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Australia Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
PRESSURE TRANSMITTER COMPACT for diaphragm seal operation
COMPACT PRESSURE TRANSMITTER for food / pharmaceutical / biotechnology
pressure transmitter
Pressure transmitter COMPACT for general applications
Compact pressure transmitter
UG2011-G2410 IMMERSION PROBE DIGITAL, stainless steel, IP68
8 Pressure transmitter,Range: 0-16bar,
Pressure Transmitter
DRUCKMESSUMFORMER
PRESSURE TRANSMITTER PASCAL CV
PRESSURE TRANSMITTER PASCAL CV Standard process connections for food, pharmaceuticals and biotechnology according to data sheet D4-017 / 22
CV3110-A1059-F10-H1100-M1-N10-T30-K2085-W4019
ø 100 mm Material: 1.4404
Resistance thermometer
THERMOMETER RESISTOR
RESISTANCE THERMOMETER Pt100 for food / pharmaceutical / biotechnology
see attached file.
Measurement And Control Devices RANGE: -50,,,200c 1*PT1003-WİRE
30Ra, 0-150C/24VDC - CofC Tube, 1/2"
(Resistance thermometer MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 11 nominal diameter: 1/2 B conical sealing C1000 temperature sensor: flush G15 material wetted parts: stainless steel material 1.4404 (316L) / PEEK FDA compliant N2 measuring insert: 1 x Pt 100 in 3-wire system, standard T150 electrical connection: circular connector M 12x1 (4-pole) using the range -50 ... + 200 ° C)
[RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology Sheet according T4-015 RTD: 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 11 nominal diameter: 1/2 B conical sealing C1 Temperature sensor: ø 6 mm 025 Installation length U1: 25 mm G11 Material wetted parts: stainless steel mat 1.4404 (316L) N3 measuring insert: 1 x Pt 100 (bridged 3-wire) in 4-wire technology T150 electrical connection: Circular connector M 12x1 (4 poles) Range of -50 ... + 200 ° C]
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 025 installation length U1: 25 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles ) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12: see below measuring range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology Sheet according T4-015 RTD: 1 x Pt 100, tolerance class A according to DIN EN 60751 GA2700-HY A10 Process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm, tapered to ø 4 mm 025 Installation length U1: 25 mm G11 Material wetted parts: stainless steel mat 1.4404 (316L) N2 Measuring insert 1 x Pt 100 in 3-wire technology, standard T150 electrical connection: Circular connector M 12x1 (4 poles) incl. transmitter in a stainless steel housing with connector M12 (Type PA2430) Z52 Transmitter for temperature (Pt 100), programmable Sheet according T4-082-1 Electrical connection: circular connector M12x1 (4-pole) PA243 0 Type: Standard F12 Configuration: see below Measuring range: 0 ... + 150 ° C Fault current to probe break: 22.8 mA Standard Sensor offset: 0 ° C Standard Damping time: 0 s, Standard
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm, tapered to ø 4 mm 030 installation length U1: 30 mm G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100 in 3-wire, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430. ) PA243 TRANSMITTER (for temperature Pt 100), programmed according to data sheet T4-082-1 electrical connection: circular connector M12x1 (4-pole) 0 Type: standard configuration F12: see below measurement range: 0 ... + 150 ° C leakage current with sensor break : 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
(GA2700-HY RESISTANCE THERMOMETER MiniTherm for food / pharmaceutical / biotechnology according sheet T4-015 measuring resistor 1 x Pt 100, tolerance class A according to DIN EN 60751 A10 process connection: threaded connection 31 Nominal diameter: M12 x 1.5 conical sealing C4 Temperature sensor: ø 6 mm tapered for a diameter of 4 mm 990 Einaulänge U1 (in mm): 20 G11 material wetted parts: stainless steel material 1.4404 (316L) N2 measurement application: 1 x Pt 100-3-wire system, standard T150 electrical connection: circular connector M 12x1 (4 poles) Z52 including transmitter in a stainless steel housing with connector M12 (type PA2430) PA243 transmitter for temperature (Pt 100), programmed according to data sheet T4-082-1 electrical connection. round connector M12x1 (4-pole) 0 type: standard configuration F12 : see below measurement range: 0 ... + 150 ° C leakage current with sensor break: 22.8 mA, standard sensor offset: 0 ° C, standard steaming time: 0 s, standard H1 output: 4 ... 20 mA, 2-wire)
(RESISTANCE THERMOMETER MiniTherm for Food / pharmaceutical / biotechnology with separate thermowell Explosion protection: without welded thermowell according to drawing B4-CA-00019-z (PG-MB-00025-k))