BRAND | Carlo Gavazzi |
Product | CTD9S7005AXXX |
Description | AC Split-Core Current Transformer |
Internal code | IMP242008 |
Weight | 1 |
Technical specification | AC Split-Core Current Transformer Type CTD-9S (max 35x125mm) • Bus-bar type split core current transformer • Class 1 accuracy • Currents from 400 A to 3200 A • Up to 10 Bus-bar isolated fixing screws • Double screw terminals (up to 8-wire connections) • Sealable terminal block covers • Sealable fixing split-core screws Product Description Ordering Key CTD-9S 2000 5AXXX Split-core current transformer with bus-bar mountng facility. Rated primary currents from 400 A to 3200 A. Model Primary current Secondary current Option Type Selection Primary current From 400A to 3200A (Refer to the Range Table) Secondary current 1A (on request) 5A Option XXX:none XTX: tropicalization (on request) InputSpecifications Operating frequency48 to 62 Hz Max. system voltage0.72 kV Rated insulation level3 kV/1 min. @ 50 Hz Insulation class E (max 75°C) Short-time current rating Ith Typical 100 In /1 s Idyn 2.5 Ith The short-timethermal current Ith is anyway limited by the cable/bus-bar size Extended current rating refer to the Range Table Security factor (FS)≤ 5 (Class: 1 and 3) General Specifications Standards According to EN60044-1 HousingABS, self-extinguishing: UL 94 V-0 MountingBus-bar mounting Standard accessoriesTwo terminal block screws. Ten cable/bus-bar fixing screws. Ten plastic caps for cable/bus-bar fixing screws. Two sealable terminal block covers. Special features1 A secondary current, Tropicalization Working temperature-25°C to: refer to the Range Table (-13°F to: refer to the Range Table) (R.H. < 90% non condensing @ 40°C) Storage temperature-30°C to +70°C (-22°F to 158°F) (R.H. < 90% non condensing @ 40°C) Approvals CE. cURus and CSA (400A to 2000A) Connection Screw type Cable cross section areaFrom 1.5 to 6 mm2 Min/Max screws tightening torque relevant to terminal block screws: From 1 to 2 Nm Max screws tightening torque relevant to the cable/bus-bar fixing screws: 0,3 Nm Protection degree IP00 (without sealable terminal covers) IP20 (with sealable terminal block covers + wire terminals) Bus-bar size Max. 35x125 mm WeightFrom 450 to 700 g |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Carlo Gavazzi - CTD9S7005AXXX AC Split-Core Current Transformer number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Germany Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
COMPACT 3-PHASE ENERGY ANALYZER REV.14
COMPACT 3-PHASE ENERGY ANALYZER REV.14
3P-SSC-DC IN-ZC 600V 3X65A 1200VP-E-CLP IN MNTR
ETHERNET/IP PORT MODULE REV.6
3PH PUMP START 220-400V 12A 110-400V I/P+O/L
3PH PUMP START 220-400V 12A 24VAC/DC I/P+O/L
3POLE 2LEG REVERSER 600VAC 3.0KW 230VAC
3POLE 2LEG REVERSER 600VAC 3.0KW 24VDC
UPROX DR SS M30 2XNPN, PLG
UPROX DR SS M30 2XNPN, CAB
UPROX DR SS M30 2XPNP, PLG
UPROX DR SS M30 2XPNP, CAB
ANNEX D COMPACT 3-PH ENERGY ANALYZER REV.0
COMPACT 3-PHASE ENERGY ANALYZER REV.14
PHOTO AMP 2CH STD NPN NO
PHOTO AMP 2CH STD PNP NC
COMPACT 3-PHASE ENERGY ANALYZER REV.14
3P-SSC-AC IN-ZC 600V 3X65A 1200VP-E-CLP IN MNTR
3P-SSC-DC IN-ZC 600V 3X65A 1200VP-E-CLP IN MNTR
COMPACT QUICK FIT ENERGY ANALYZER REV.13
COMPACT QUICK FIT ENERGY ANALYZER REV.5
3_PHASE SPLIT-CORE CURRENT SENSORS EM271 REV.2
ANNEX D COMPACT 3-PHASE ENERGY METER REV.0
COMPACT 3-PHASE ENERGY ANALYZER REV.14
COMPACT 3-PHASE ENERGY ANALYZER REV.14
3PH PUMP START 220-400V 16A 110-400V I/P+O/L
3PH PUMP START 220-400V 16A 24VAC/DC I/P+O/L
3PH PUMP START 220-400V 25A 110-400V I/P
3PH PUMP START 220-400V 25A 24VAC/DC I/P
Solid State Relay