BRAND | Loreme |
Product | IPL50/S |
Description | CURRENT METER |
Internal code | IMP4797254 |
Technical specification | Built in enclosure, 96 x 48 mm Measure - AC, DC measures : voltage, current, power - Frequency, cos phi, active power, reactive power, apparent power - Single phase, balanced Three phases, with or without neutral - CT and PT ratio configurable Inputs - Voltage 0...125 Vac, +/- 175 Vdc - Or Voltage 0...500 Vac, +/- 700 Vdc - Current 0...1 Aac, +/- 1 Adc - Or Current 0...5 Aac, +/- 5 Adc - Frequency : 40...400 Hz - Operating inputs : * Voltage : By your own * Current : By your own * Frequency : By your own Relays output - 2x changeover relays, freee potential contacts Display - 4 digits LED 7 segments, 10 000 points - Display of selected measure, fixe or scrolling mode, threshold setting Power supply - 20...70 Vac/dc or 80...265 Vac/dc Setting - USB link (USB cable as option) Option /S - 2x analog outputs, common negative point - Configurable : Current 0...20 mA or Voltage 0...10 Vdc |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Loreme - IPL50/S CURRENT METER number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Germany Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Multi-Output Loop Isolator
Alternating current and voltage converter
Digital Converter
high voltage isolation numeric converter
Mounting : - wall mount and DIN rail, box 50 x 70 x 113 mm Input : - Pt100, thermocouple mV, mA, Ohms Output : - current 0…4….20 mA, voltage 0 to 10 V Relay : - switching contact, floating contact Power supply : - 230/115 Vac switchable (our voltage on request) Isolation : - power supply/input/output/relay 1500 Vac Parametrisation : - RS232 link (cable supplied separately)
digital converter
PROGRAMMABLE POWER CONVERTER CPL101
LEVEL INDICATOR
PROGRAMMABLE NETWORK INDICATOR - Power supply : 127 VDC - Current input I1, I2, I3 = 1A - Voltage input U1, U2, U3 = 150V Rotation T1 = 1, TP = 60 - No output relay, no analog output - With RS485 Modbus on SLOT n°? (Please specify on which Slot you need the RS485) - ALSTOM making (Threaded rods)
electrical network analyser
CURRENT METER
230VDC
TEMPERATURE SENSOR 100? -0 DEGREE REF NO: 100 SE 079 MESA
(PROGRAMMING LINK CABLE, To configure the here above device)
Precision current shunt
SCREW-IN RTD PROBE
Dext=16mm, Dint=6,5mm, 1/2" NPT mâle (1)
TRANSDUCER
Universal Digital Converter
LINK CABLE /USB
converter
resistive level probe