BRAND | Hbm |
Product | K-SP4M-N-C3MR-5-N-6-A |
Internal code | IMP4907495 |
Technical specification | SP4M scale with options way N Standard version Accuracy class C3MR C3MR Explosion-proof protection N Without protection explosion-proof Cable length 6 6m Others A 2mV/V+/-0.1% 410Ohm ±0.2Ohm TK0 0.5 Vmin = 0.5g |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Hbm - K-SP4M-N-C3MR-5-N-6-A number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Germany Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Type HLM-20242 Output 1.8 millivolts load cell
Emax: 2.2 t, Emin: 0 kg, Limit: 3.3 t Vmin: 220 g, Cn; 1.94 mv/v; TC2163
Load cell
(Calibration of the measured variable force in accordance with the HBM standard (without connector assembly). Traceability by DAkkS accreditation guaranteed by ISO 17025 or at factory calibrations (WCS) in Reference to ISO 10012 Calibration certificate in German and English Calibration type force DAkkS ISO 376, 8 steps Calibration power <= 1 MN Of load power tension and compression Number of measuring bridges Power Easy Bridge TEDS TEDS programming without programming)
Calibration of the measured variable torque according HBM standard (Without connector or coupling assembly. Traceability through accreditation ISO 17025 (DKD) guarantees In DAkkS / DKD - calibrations optionally by: DIN 51309, EURAMET / cg-14, VDI2646 (Teilbereichskal. Not possible) DKD-R 3-5 (turning moment), or DKD-R 3-7 (transfer torque wrench). Factory calibrations (WCS) in relation to ISO 10012th Calibration certificate in German and English Calibration type torque WKS, 6 steps, 1 + 1 measurements Measuring range <= 200Nm Load direction right and left Moment Number outputs an output signal TEDS TEDS programming without programming 1. Signal output mV / V 2. Signal output 0
Calibration of the measured variable torque according HBM standard (Without connector or coupling assembly. Traceability through accreditation ISO 17025 (DKD) guarantees In DAkkS / DKD - calibrations optionally by: DIN 51309, EURAMET / cg-14, VDI2646 (Teilbereichskal. Not possible) DKD-R 3-5 (turning moment), or DKD-R 3-7 (transfer torque wrench). Factory calibrations (WCS) in Terms of ISO 10,012th Calibration certificate in German and English Calibration type torque WKS, 6 steps, 1 + 1 measurements Measuring range <= 10kNm Load direction right and left Moment Number outputs an output signal TEDS TEDS programming without programming 1. Signal output mV / V
technology özllkler ksmnda blgi was
Absolute Pressure Measuring system: strain gauge 350 Ohm
(K-RTNaa / bbb cccc dd eee Compact RTN load cell as a variant in special design DMS-measuring system (4000 ohms), nominal characteristic value 2.85 mV / V, with fixed cable, free ends, IP68 protection to EN 60,529th design standard Accuracy class C3 Rated load 150t Explosion protection No explosion Cable length 12m Others without TK0 without Country / customer default Creep 20 ° C Standard)
3-way rosette 1.5, 350 OHM LUK / SENSOR / 3Set floors form
(K-U15 Force transducers for tensile and compression forces Class 0.5 to ISO 376 Class only guaranteed with the optionally available DKD calibration DMS-measuring system 350 Ohm Nominal sensitivity of 2 mV / V (2.5 kN ... 10 kN) Nominal characteristic value 3 mV / V (25 kN 1 ... MN) Nominal force 250kN Measuring bridge number Simple bridge Transducer identification TEDS without Inlet Protection without plug Protection Mating guide bridge A bayonet connector Parameter adjusted)
Process Controller
8-channel universal amplifier of QuantumX family
Plattform-Wägezelle für dynamische Verwiegung
Terminal Box for 4 Load Cells
load cell
loadcell
loadcell
load cell
Scherstabwägezelle Z7AC3/2t
loadcell
Force transducer