Buy MR8870 from Hioki in Germany

BRAND Hioki
Product MR8870
Description MEMORY HiCORDER
Internal code IMP796506
Weight 1
Technical specification Number of channels 2 analog channels + 4 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND Measurement ranges 10 mV to 50 V/div (10 div full-scale), 12 ranges, Resolution: 1/100 of range Max. rated voltage Between terminals: 400 VDC, Between terminal to earth: 300 VAC, DC CAT II Frequency characteristics DC to 50 kHz (-3 dB) Time axis (Memory mode) 100 µs to 5 min/div, 20 ranges,at 100 points/div resolution, three steps of time-axis magnification from ×2 to ×10, and 9 steps of time-axis compression from ×1/2 to ×1/1,000 Recording intervals (RMS mode) 1 ms to 1 min., 16 settings, sampling period: 200 μs (fixed) (for AC voltage/current, 1,000 RMS values/sec.), envelope mode always on Note: Only the maximum value and minimum value for each recording interval are recorded. Measurement functions Memory recorder (high speed recording), RMS recorder (50/60 Hz, DC only) Memory capacity 12-bits × 2M-words/ch (1 word = 2 bytes) Removable storage CF card TYPE I slot ×1 (Up to 2 GB) Display 4.3-inch WQVGA-TFT color LCD (480 × 272 dots) Displayable languages English, Japanese Interfaces USB 2.0 mini-B receptacle ×1, Functionality: Connect the instrument to a PC to send files on the CF card to the PC. The instrument cannot be controlled from a PC. Printer N/A Power supply AC Adapter Z1005: 100 to 240 VAC (50/60 Hz) , 30 VA max. (when using the AC adapter and charging the 9780 with the instrument) Battery Pack 9780: 3 VA, continuous operating time of approx. 2 hr. (25°C reference value; when used with the Z1005, the Z1005 takes priority), charging time of 200 min. using the AC adapter (25°C reference value) (option) External DC power: 10 to 16 V, 10 VA max. (connection cord of 3 m or less is available by special-order) Dimensions and mass 176 mm (6.93 in)W × 101 mm (3.98 in)H × 41 mm (1.61 in)D, 600 g (21.2 oz) (with the Battery pack 9780 installed)

Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Hioki - MR8870 MEMORY HiCORDER number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Germany Industrial products Market.

WE SELL ONLY NEW AND ORIGINAL PRODUCTS!

More products of Hioki

C1006

Carrying Type

RM3548

Resistance Meter

9453

Four termal lead

L2107

Clip type lead

FT3470-51

Tester

3288

Current clamp 1000 A AC/DC

3554. obsolete

Battery Hitester

BT3554

Battery Tester

LR-8431

Memory HiLogger

IR4056-20

Digital Meg-Ohm Insulation Tester

3490

Insulation meter

3246-60

Penlight DMM

3151

Earth HiTester

FT3700-20

Infrared Thermometer

Calibration certificate for Hioki FT3700-20

Factory Calibration Certificate - No Data

9140-10

TERMINAL PROBE

Contact us for request