BRAND | Knick |
Product | SE 604X-MS |
Description | Conductivity Sensors |
Internal code | IMP4994886 |
Please send us your request per e-mail, so we can send you our offer with competitive prices and delivery time for Knick - SE 604X-MS Conductivity Sensors number or any other model you need. We can offer competitive price, and delivery time with wide products distribution network in Germany Industrial products Market.
WE SELL ONLY NEW AND ORIGINAL PRODUCTS!
Standard signal isolator
Isolation Amplifiers
DC-Isolation Amplifier
(81464 Standard signal isolator VariTrans Type H1: with pluggable screw Input: 0/4 ... 20 mA, 0 ... 10 V switchable Output: 0/4 ... 20 mA (max 600 Ohm.) 0 ... 10 V switchable Power supply: 20 ... 253 V AC / DC)
Universal Isolated Signal Conditioner
81463 Universal separator Type H1: with pluggable screw Input: adjustable or switchable from 20 mV ... 200 V or 0.1 mA ... 100 mA unipolar / bipolar Default: ± 10 V Output: 10 V, 20 mA, 5 V, 4 ... 20 mA switchable Default: ± 10 V Power supply: 20 ... 253 V AC / DC
81463 Universal separator Type H1: with pluggable screw Input: adjustable or switchable from 20 mV ... 200 V or 0.1 mA ... 100 mA unipolar / bipolar Output: 10 V, 20 mA, 5 V, 4 ... 20 mA switchable Power supply: 20 ... 253 V AC / DC
81463 Universal separator Type H1: with pluggable screw Input: adjustable or switchable from 20 mV ... 200 V or 0.1 mA ... 100 mA unipolar / bipolar Output: 10 V, 20 mA, 5 V, 4 ... 20 mA switchable Power supply: 20 ... 253 V AC / DC
58285 Universal separator Construction F1: with fixed screw Input: set of bzw.umschaltbar 20 mV ... 200 V or 0.1 mA ... 100 mA unipolar / bipolar Output: 10 V, 20 mA, 5 V, 4 ... 20 mA switchable Power supply: 20 ... 253 V AC / DC
Universal Isolator
Universal separator
transducer
Temperature Transmitter
[68715 High voltage disconnectors VariTrans with calibrated switchable areas Input: ± 60/90/150/300/500 mV / V 10 Output: ± 10 V / ± 20 mA / 4 ... 20 mA Working voltage (basic insulation): 2.2 kV AC / DC Test voltage: 10 kV AC Power supply: 20 ... 253 V AC / DC]
68715 High voltage disconnectors VariTrans with calibrated switchable areas Input: ± 60/90/150/300/500 mV / V 10 Output: ± 10 V / ± 20 mA / 4 ... 20 mA Working voltage (basic insulation): 2.2 kV AC / DC Test voltage: 10 kV AC Power supply: 20 ... 253 V AC / DC
High voltage disconnectors
TRANSDUCER
TRANSDUCER
TRANSDUCER VARITRANS
TRANSDUCER, DC, VARITRANS
TRANSDUCER DC VARITRANS
[68717 High voltage disconnectors VariTrans with calibrated switchable areas Input: ± 400/600/800/1000/1200 V Output: ± 10 V / ± 20 mA / 4 ... 20 mA Delivery setting: Input ± 1200 V / Output ± 10 V.. Working voltage (basic insulation): 2.2 kV AC / DC Test voltage: 10 kV AC power supply: 20 ... 253 V AC / DC]
TRANSDUCER
High voltage isolators
High voltage disconnectors
High Voltage Transducer
relay
electrode cell for conductivity
2-electrode sensor